Diferencia entre revisiones de «EBQ:End-Tidal CO2 Monitoring»
| Línea 18: | Línea 18: | ||
==Conclusion== | ==Conclusion== | ||
ETCO₂ monitoring identified the majority of acute respiratory events during PSA, and in 70% of these cases, abnormalities were detected before clinical recognition via SpO₂ or observed hypoventilation. ETCO₂ monitoring offers earlier detection of respiratory compromise than current standard practices. | |||
==Major Points== | ==Major Points== | ||
Revisión del 03:20 4 may 2025
incomplete Journal Club Article
Burton J. et al.. "Does end-tidal carbon dioxide monitoring detect respiratory events prior to current sedation monitoring practices?". Acad Emerg Med. 2006. 13(5):500-4.
PubMed Full text PDF
PubMed Full text PDF
Clinical Question
Can end-tidal carbon dioxide (ETCO₂) monitoring during emergency department procedural sedation and analgesia (PSA) detect acute respiratory events earlier than standard monitoring methods (e.g., SpO₂, clinical observation)?
Conclusion
ETCO₂ monitoring identified the majority of acute respiratory events during PSA, and in 70% of these cases, abnormalities were detected before clinical recognition via SpO₂ or observed hypoventilation. ETCO₂ monitoring offers earlier detection of respiratory compromise than current standard practices.