Diferencia entre revisiones de «Anion gap»

Sin resumen de edición
Sin resumen de edición
Línea 42: Línea 42:
**[[Lithium Toxicity]]
**[[Lithium Toxicity]]
*Increased cationic paraprotein
*Increased cationic paraprotein
*Multiple myeloma
*[[Multiple myeloma]]
**Polyclonal IgG gammopathy
**Polyclonal IgG gammopathy
*Pseudo
*Pseudo

Revisión del 22:31 18 feb 2016

Background

A normal gap is 12 +/- 4 (i.e. 8 to 16). The anion gap is the difference between measured cations and measured anions in serum. This difference does not reflect a true disparity between positive and negative charges, given that serum actually is electrically neutral when all serum cations and anions are measured. Rather, the anion gap is a measurement artifact resulting from the fact that only certain cations and anions are routinely measured. Anion gap metabolic acidosis is secondary to the addition of endogenous or exogenous acid

  • AG = Na - (Cl + HCO3)
  • Normal Anion Gap = 12+/-4 (8-16)

Cutoffs for "normal" Anion Gap are laboratory and equipment specific. Newer technology and equipment have been shown to measure "low" AG in otherwise normal, healthy people.[1][2]

Elevated Anion Gap

Differential Diagnosis

MUDPILES

Also:

KILR

Low Anion Gap

Differential Diagnosis

  • AG falls by 2.5 meq/L for every 1 g/dL reduction in albumin concentration

See Also

Anion Gap and Osmolar Gap (High)

Sources

  1. Jurado RL, del Rio C, Nassar G, Navarette J, Pimentel JL Jr. "Low anion gap." South Med J. 1998;91(7):624
  2. Winter SD, Pearson JR, Gabow PA, Schultz AL, Lepoff RB. "The fall of the serum anion gap." Arch Intern Med. 1990;150(2):311