Weaning Paramater
- PaO2/FiO2 >200
- Tidal volume 5cc/kg
- RR <40
- Vital cap 10cc/kg
- Min vent. <10L/min
greater predictive value
- max inspir. pressure greater -90cmH2O female
- -120 male threshold -25 cm h2o
- RSBI: rate/tidal volume < 100 min/L.