==Background==
==Background==
*Used for delivery of short or long acting pain or anti-spasmodic medications into the thecal space
*Allows for smaller doses and fewer systemic side effects
*Most common Intrathecal medications
**[[Clonidine]]
**[[Bupivacaine]]
**[[Morphine]]
**[[Hydromorphone]]
**[[Fentanyl]]
**[[Baclofen]]
**[[Ziconotide]]


==Clinical Features==
==Clinical Features==


==Differential Diagnosis==
==Differential Diagnosis==
Complications:
*Overdose of medication, see:
**[[Opioid toxicity]]
**[[Clonidine toxicity]]
**[[Local anesthetic systemic toxicity]]
**[[Baclofen toxicity]]
**[[Respiratory failure|Respiratory depression]] is feared effect of most
*[[Infection]]
**Local [[cellulitis]]
**[[Meningitis]]


==Diagnosis==
==Evaluation==


==Management==
==Management==
*The device is not removed in an overdose but should be turned off.
*Insertion of a 22-guage needle into the pump reservoir can remove all medication in case device cannot be turned off
*Consider [[naloxone]] to reverse opioid effects taking into account patients chronicity of treatment if they withdrawal
*Treat infection aggressively with [[antibiotics]]
**May be treated without device removal with combination of IV and intrathecal antibiotics<ref>Aristedis R, Dimitrios P, Nikolaos P, Alexandros B. Intrathecal baclofen pump infection treated by adjunct intrareservoir teicoplanin instillation. Surg Neurol Int. 2017;8:38.</ref>, but consult ID and/or anesthesia/appropriate surgical specialty as device may need to be removed


==Disposition==
==Disposition==
Línea 13: Línea 38:
==See Also==
==See Also==
*[[Medical device complications]]
*[[Medical device complications]]
*[[Baclofen toxicity]]


==External Links==
==External Links==
Línea 18: Línea 44:
==References==
==References==
<references/>
<references/>
[[Category:Surgery]]
[[Category:Neurology]]

Revisión actual - 16:37 5 nov 2025

Background

Clinical Features

Differential Diagnosis

Complications:

Evaluation

Management

  • The device is not removed in an overdose but should be turned off.
  • Insertion of a 22-guage needle into the pump reservoir can remove all medication in case device cannot be turned off
  • Consider naloxone to reverse opioid effects taking into account patients chronicity of treatment if they withdrawal
  • Treat infection aggressively with antibiotics
    • May be treated without device removal with combination of IV and intrathecal antibiotics[1], but consult ID and/or anesthesia/appropriate surgical specialty as device may need to be removed

Disposition

See Also

External Links

References

  1. Aristedis R, Dimitrios P, Nikolaos P, Alexandros B. Intrathecal baclofen pump infection treated by adjunct intrareservoir teicoplanin instillation. Surg Neurol Int. 2017;8:38.