==Clinical Features==
==Clinical Features==
*Desaturation, other vital sign abnormalities, or cardiac arrest while on mechanical ventilation
*Desaturation, other vital sign abnormalities, or [[cardiac arrest]] while on mechanical ventilation


==Differential Diagnosis==
==Differential Diagnosis==
===DOPE<ref>EMRA Critical Care Handbook</ref><ref>Monica E. Kleinman et al. Pediatric Advanced Life Support: 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. AAP. 2010. http://pediatrics.aappublications.org/content/126/5/e1361.full</ref>===
===DOPES<ref>EMRA Critical Care Handbook</ref><ref>Monica E. Kleinman et al. Pediatric Advanced Life Support: 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. AAP. 2010. http://pediatrics.aappublications.org/content/126/5/e1361.full</ref>===
*'''D'''isplaced ETT
*'''D'''isplaced ETT
*'''O'''bstruction (anywhere along circuit)
*'''O'''bstruction (anywhere along circuit)
*[[Pneumothorax|'''P'''neumothorax]]
*[[Pneumothorax|'''P'''neumothorax]]
*'''E'''quipment failure (ventilator malfunction or disconnect)
*'''E'''quipment failure (ventilator malfunction or disconnect)
*'''S'''tacked breaths (asthmatics)


==Evaluation==
==Evaluation==
Línea 19: Línea 20:
===Troubleshoot===
===Troubleshoot===
''Immediately disconnect from ventilator (allows for expiration of stacked breaths)''
''Immediately disconnect from ventilator (allows for expiration of stacked breaths)''
*D - Displacement of tube
*D - Displacement of tube or cuff
**Attach end-tidal CO2 to verify and check depth (cm at lip)
**Attach end-tidal CO2 to verify and check depth (cm at lip)
*O - Obstruction of tube/circuit
*O - Obstruction of tube/circuit
**Use suction catheter to remove mucus plug, or make sure patient not biting down
**Use suction catheter to remove mucus plug, or make sure patient not biting down, look for kink in tube
*P - Pneumothorax
*P - [[Pneumothorax]]
**Verify via [[Ultrasound: Lungs|ultrasound]], CXR, or [[needle thoracostomy]] (high suspicion)
**Verify via [[Ultrasound: Lungs|ultrasound]], CXR, or [[needle thoracostomy]] (high suspicion)
*E - Equipment failure
*E - Equipment failure
Línea 35: Línea 36:
*O - Oxygen 100% BVM. Look for chest rise, listen and feel for cuff leak
*O - Oxygen 100% BVM. Look for chest rise, listen and feel for cuff leak
*T - Tube position and patency.  Pass bougie or suction all the way through tube to remove obstruction
*T - Tube position and patency.  Pass bougie or suction all the way through tube to remove obstruction
*T - Tweak the vent.  Usually need to decrease respiratory rate (see below on breath-staking)
*T - Tweak the vent.  Usually need to decrease respiratory rate, decreased inspiratory time with changing E:I ratio (see below on breath-staking)
*S - Sonography and CXR
*S - Sonography and CXR


Línea 45: Línea 46:
*Decrease TV
*Decrease TV
*Increase sedation
*Increase sedation
===Peak Vs Plateau Pressure===
*Super important to keep alveolar pressure low to prevent barotrauma
*Peak Pressure is pressure of entire system (vent, ET tube, trachea, bronchus, bronchioles, alveoli). High peak pressure does not equal barotrauma
*Plateau pressure - check with button on vent (may say plateau pressure or end-inspiratory hold)
*High Peak and Normal Plateau - problem with vent, ET tube, bronchoconstriction (reactive airway disease/asthma/COPD).
*High Peak and High Plateau - Compliance issue (pneumothorax, problem with alveoli like ARDS, fluid overload). Need to decrease pressure to prevent barotrauma.
*Plateau pressures should be kept < 30mmHg if possible.
[[File:ardsnet.jpg|thumb|[http://www.ardsnet.org/files/ventilator_protocol_2008-07.pdf ARDS net ventilator protocol ]]]
{{Lung Protective FiO2 and PEEP Scale}}


==See Also==
==See Also==
{{Mechanical ventilation pages}}
{{Mechanical ventilation pages}}
{{Related Difficult Airway Pages}}
==External Links==
*https://rebelem.com/rebel-cast-ep-46b-vent-management-crashing-patient-haney-mallemat/


==References==
==References==
Línea 54: Línea 70:
[[Category:Pulmonary]]
[[Category:Pulmonary]]
[[Category:Critical Care]]
[[Category:Critical Care]]
(https://rebelem.com/rebel-cast-ep-46b-vent-management-crashing-patient-haney-mallemat/)
**DOPES = Displaced ET tube or cuff, Obstructed ET tube: pt biting tube, kink in tube, mucous plug, Pneumothorax, Equipment: Tube from ETT to Vent, Stacked breaths: auto-PEEP (typically asthma/COPD, results from decreased ability to expire air)
**DOTTS = Disconnect from vent (can push down on pt’s chest if concern for auto-PEEP), FOR COVID-19 SKIP Oxygenate with 100% BVM (evaluates for ETT dislodgement, bilateral breath sounds, cuff leak, crepitus, difficulty bagging),  Tube check for mucous plug or kink or dislodgement, Tweak vent for autoPEEP (decreased RR, decreased inspiratory time with changing E:I ratio), Sonography for pneumothorax.

Revisión actual - 16:10 24 abr 2024

Background

  • There are multiple reasons for a patient to deteriorate while on mechanical ventilation
  • A systematic method of evaluating this deterioration is the best way to identify/fix the causative problem

Clinical Features

  • Desaturation, other vital sign abnormalities, or cardiac arrest while on mechanical ventilation

Differential Diagnosis

DOPES[1][2]

  • Displaced ETT
  • Obstruction (anywhere along circuit)
  • Pneumothorax
  • Equipment failure (ventilator malfunction or disconnect)
  • Stacked breaths (asthmatics)

Evaluation

  • Clinical

Management

Troubleshoot

Immediately disconnect from ventilator (allows for expiration of stacked breaths)

  • D - Displacement of tube or cuff
    • Attach end-tidal CO2 to verify and check depth (cm at lip)
  • O - Obstruction of tube/circuit
    • Use suction catheter to remove mucus plug, or make sure patient not biting down, look for kink in tube
  • P - Pneumothorax
  • E - Equipment failure
    • Connect to BVM
  • S - Stacked breaths - Auto-PEEP especially in COPD/Asthma
    • Disconnect from ventilator

Fix

  • "DOTTS" Mnemonic
  • D - Disconnect ventilator and put light pressure on patient chest
  • O - Oxygen 100% BVM. Look for chest rise, listen and feel for cuff leak
  • T - Tube position and patency. Pass bougie or suction all the way through tube to remove obstruction
  • T - Tweak the vent. Usually need to decrease respiratory rate, decreased inspiratory time with changing E:I ratio (see below on breath-staking)
  • S - Sonography and CXR

Auto-PEEP (Breath stacking) troubleshooting options

  • Bronchodilators if COPD/asthma
  • Decrease RR
  • Decrease I:E ratio (increase expiratory time)
  • Quicker inspiratory flow rate
  • Decrease TV
  • Increase sedation

Peak Vs Plateau Pressure

  • Super important to keep alveolar pressure low to prevent barotrauma
  • Peak Pressure is pressure of entire system (vent, ET tube, trachea, bronchus, bronchioles, alveoli). High peak pressure does not equal barotrauma
  • Plateau pressure - check with button on vent (may say plateau pressure or end-inspiratory hold)
  • High Peak and Normal Plateau - problem with vent, ET tube, bronchoconstriction (reactive airway disease/asthma/COPD).
  • High Peak and High Plateau - Compliance issue (pneumothorax, problem with alveoli like ARDS, fluid overload). Need to decrease pressure to prevent barotrauma.
  • Plateau pressures should be kept < 30mmHg if possible.

Lung Protective FiO2 and PEEP Scale[3][4][5]

FiO2 0.3 0.4 0.4 0.5 0.5 0.6 0.7 0.7 0.7 0.8 0.9 0.9 0.9 1.0 1.0 1.0
PEEP 5 5 8 8 10 10 10 12 14 14 14 16 18 20 22 24

See Also

Mechanical Ventilation Pages

Airway Pages

External Links

References

  1. EMRA Critical Care Handbook
  2. Monica E. Kleinman et al. Pediatric Advanced Life Support: 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. AAP. 2010. http://pediatrics.aappublications.org/content/126/5/e1361.full
  3. The Acute Respiratory Distress Syndrome Network. Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. The Acute Respiratory Distress Syndrome Network. N Engl J Med. 2000;342(18):1301-1308.
  4. Kallet RH, et al. "Respiratory controversies in the critical care setting. Do the NIH ARDS Clinical Trials Network PEEP/FIO2 tables provide the best evidence-based guide to balancing PEEP and FIO2 settings in adults?" Respiratory Care. 2007. 52(4):461-75.
  5. ARDSnet protocol card