Diferencia entre revisiones de «Transcutaneous pacing»

 
(No se muestran 5 ediciones intermedias de 3 usuarios)
Línea 8: Línea 8:
**Malfunction of implanted pacemaker
**Malfunction of implanted pacemaker
*[[Tachyarrhythmias]] causing hemodynamic impairment<ref name="AHA"></ref>
*[[Tachyarrhythmias]] causing hemodynamic impairment<ref name="AHA"></ref>
==Contraindications==


==Procedure==
==Procedure==
Línea 16: Línea 19:
**Pad on lead V3 position and between left scapula and T-spine
**Pad on lead V3 position and between left scapula and T-spine
*Set: HR 80, pacing threshold usually between 40-80 mA
*Set: HR 80, pacing threshold usually between 40-80 mA
**If hemodynamically unstable or with evidence of end organ poor perfusion start at 80 mA and titrate down as tolerated.
**Look for clear QRS complex and T-wave following pacer spike
**Look for clear QRS complex and T-wave following pacer spike
**Check pulse to confirm mechanical capture
**Check pulse to confirm mechanical capture
Línea 23: Línea 27:
*[[ACLS: Bradycardia]]
*[[ACLS: Bradycardia]]
*[[Transvenous pacing]]
*[[Transvenous pacing]]
==External Links==
*[https://www.acepnow.com/article/transcutaneous-transvenous-cardiac-pacing/ ACEP - Transcutaneous and Transvenous Cardiac Pacing]
*[https://www.downeastem.org/common-bedside-procedures-1 Downeast EM - Transcutaneous Pacing]


==References==
==References==

Revisión actual - 18:44 17 abr 2024

Background

Indications

Contraindications

Procedure

True electrical capture
False capture with visible phantom beats[2]
  • Pad placement:
    • Pad on apex of heart and on right upper chest
    • Pad on lead V3 position and between left scapula and T-spine
  • Set: HR 80, pacing threshold usually between 40-80 mA
    • If hemodynamically unstable or with evidence of end organ poor perfusion start at 80 mA and titrate down as tolerated.
    • Look for clear QRS complex and T-wave following pacer spike
    • Check pulse to confirm mechanical capture
    • Final current set 5-10 mA above threshold level for patient

See Also

External Links

References

  1. 1.0 1.1 Epstein AE, DiMarco JP, Ellenbogen KA, et al. ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices): developed in collaboration with the American Association for Thoracic Surgery and Society of Thoracic Surgeons. Circulation. May 27 2008;117(21):e350-408