Diferencia entre revisiones de «Needle thoracostomy»

(Text replacement - "* " to "*")
Sin resumen de edición
Línea 6: Línea 6:
*14 to 16 gauge IV needle/catheter
*14 to 16 gauge IV needle/catheter
*5 or 10mL syringe
*5 or 10mL syringe
==Procedure==
==Procedure==
*Insert 14 to 16 gauge IV needle catheter attached to syringe along superior margin of 2nd or 3rd rib in midclavicular line
*Insert 14 to 16 gauge IV needle catheter attached to syringe along superior margin of 2nd or 3rd rib in midclavicular line
Línea 13: Línea 14:
*Immediate rush of air out of chest = tension pneumothorax
*Immediate rush of air out of chest = tension pneumothorax
*Follow immediately with standard thoracostomy tube
*Follow immediately with standard thoracostomy tube
==Complications==
==Complications==
*Kinking of catheter
*Kinking of catheter
Línea 24: Línea 26:


==External Links==
==External Links==


==References==
==References==
<references/>


<references/>
*Doelken P, et al. Placement and management of thoracostomy tubes. In: Post T, ed. UpToDate. Waltham, Mass.: UpToDate; 2014. www.uptodate.com. Accessed December 25, 2014. 
[[Category:Procedures]]
[[Category:Procedures]]

Revisión del 06:52 13 jul 2017

Indications

Equipment Needed

  • 14 to 16 gauge IV needle/catheter
  • 5 or 10mL syringe

Procedure

  • Insert 14 to 16 gauge IV needle catheter attached to syringe along superior margin of 2nd or 3rd rib in midclavicular line
  • Advance needle until air is aspirated to syringe
  • Withdraw needle
  • Leave angiocatheter open to air
  • Immediate rush of air out of chest = tension pneumothorax
  • Follow immediately with standard thoracostomy tube

Complications

See Also

External Links

References